AC Refrigerant Leak Repair — Lancaster County, PA
Low refrigerant is the #1 cause of AC not cooling properly. But refrigerant doesn't "run out" — if it's low, you have a leak. Finding and fixing the leak is the only real solution.
Our AC Leak Repair Process
- Pressure check: Verify system is low on refrigerant
- Leak detection: Electronic detector + UV dye to locate all leak points
- Leak repair: Solder, braze, or replace fitting/component as appropriate
- Pressure test: Nitrogen pressure test to verify repair holds
- Vacuum: Pull system down to remove all moisture and air
- Recharge: Charge to manufacturer specification by weight
- Performance test: Verify proper temperature split and system operation
Common Leak Locations
- Evaporator coil — most common on older Carrier/Lennox systems
- Service valve fittings
- Flare connections at line set
- Condenser coil (from physical damage or corrosion)
Call (717) 483-1673 for EPA-certified leak diagnosis and repair.